Products > FREIGHT ELEVATOR > View Technical Information  
   
Type Loading
Capacity
(kg)
Speed
(m/min)
Car
A x B
Entrance Elevator Path
Machine Room Over
head
(OH)
Pit
(P)
Reaction Force(kg)
W H X Y YT S x T R1 R2
F800 2S 800 30
45
1300 x 2300 1100 2100 2200 2950 3200 4000 x 3000 4550 1300 6200 4000
F1000 2S 1000 1700 x 2300 1300 2600 2950 3200 7500 6000
F1500 2S 1500 2200 x 2400 1500 3100 3100 3300 5000 x 3100 9500 6500
F800 2U 800 1400 x 2000 1400 2100
~
2500
2300 2600 2750 4000 x 2600 4450
~
4850
6200 4000
F1000 2U 1000 1800 x 2000 1800 2700 2600 2750 4500 x 2600 7500 6000
F1500 2U

           3U
1500 2200 x 2400 2200 3100 3000 3150 5000 x 3000 9500 6500
3100 3350 5000 x 3100
F2000 2U

           3U
2000 2200 x 3000 3600 3750 5000 x 3600 12800 9000
3700 3950 5000 x 3700
F2500 2U

           3U
2500 2500 x 3000 2500 3400 3600 3750 5500 x 3600 14300 10800
3700 3950 5500 x 3700
F3000 2U

           3U
3000 2700 x 3300 2700 3600 3900 4050 5500 x 3900 19000 12800
4000 4250 5500 x 4000
Minimum Story Height according to STORY DOOR type ()   2U : H x 1.5 +600    3U : H x (4/3) +600
H=Height of Entrance  YT=Penetration Type
1. Please consider construction error since dimension of elevator path is the minimum value.
2. Please construct the wall of elevator path over 150 thick.
   
 
 
Type Loading
Capacity
(kg)
Speed 
(m/min)
Car
A x B
Entrance Elevator Path
Machine Room Over
head
(OH)
Pit
(P)
Reaction Force (kg)
W H X Y YT S x T R1 R2 R3 R4
F1000 2U 1000 20 1800 x 2000 1800 2100 2700 2600 2750 2500 x 3000 2100 4450
1300 1150 1800 6900 14800
F1500 2U

           3U
1500 2200 x 2400 2200 3100 3000 3150 300 3900 8000 20600
3100 3350
F2000 2U

           3U
2000 2200 x 3000 2500 3600 3750 3000 x 3500 4850
400 4800 9000 25400
3700 3950
F2500 2U

           3U
2500 2500 x 3000 2500 3400 3600 3750 400 5400 9700 28800
3700 3950
F3000 2U

           3U
3000 2700 x 3300 2700 3600 3900 4050 3200 x 4600 700 5900 16400 31500
4000 4250
F5000 2U
           3U
5000 3200 x 4800 3200 4350 5400 5700 5000 1400 6400 18500 32400
Minimum Story Height according to STORY DOOR type ()   2U : H x 1.5 +600    3U : H x (4/3) +600
H=Height of Entrance  YT=Penetration Type
1. Please consider construction error since dimension of elevator path is the minimum value.
2. Please construct the wall of elevator path over 150 thick.