Products > FREIGHT ELEVATOR > View Technical Information  
   
Type Loading
Capacity
(kg)
Speed
(m/min)
Car
A x B
Entrance Elevator Path
Machine Room Over
head
(OH)
Pit
(P)
Reaction Force(kg)
W H X Y YT S x T R1 R2
F800 2S 800 30
45
1300 x 2300 1100 2100 2200 2950 3200 4000 x 3000 4550 1300 6200 4000
F1000 2S 1000 1700 x 2300 1300 2600 2950 3200 7500 6000
F1500 2S 1500 2200 x 2400 1500 3100 3100 3300 5000 x 3100 9500 6500
F800 2U 800 1400 x 2000 1400 2100
~
2500
2300 2600 2750 4000 x 2600 4450
~
4850
6200 4000
F1000 2U 1000 1800 x 2000 1800 2700 2600 2750 4500 x 2600 7500 6000
F1500 2U

           3U
1500 2200 x 2400 2200 3100 3000 3150 5000 x 3000 9500 6500
3100 3350 5000 x 3100
F2000 2U

           3U
2000 2200 x 3000 3600 3750 5000 x 3600 12800 9000
3700 3950 5000 x 3700
F2500 2U

           3U
2500 2500 x 3000 2500 3400 3600 3750 5500 x 3600 14300 10800
3700 3950 5500 x 3700
F3000 2U

           3U
3000 2700 x 3300 2700 3600 3900 4050 5500 x 3900 19000 12800
4000 4250 5500 x 4000
Minimum Story Height according to STORY DOOR type (§®)   2U : H x 1.5 +600    3U : H x (4/3) +600
H=Height of Entrance  YT=Penetration Type
1. Please consider construction error since dimension of elevator path is the minimum value.
2. Please construct the wall of elevator path over 150§® thick.
   
 
 
Type Loading
Capacity
(kg)
Speed 
(m/min)
Car
A x B
Entrance Elevator Path
Machine Room Over
head
(OH)
Pit
(P)
Reaction Force (kg)
W H X Y YT S x T R1 R2 R3 R4
F1000 2U 1000 20 1800 x 2000 1800 2100 2700 2600 2750 2500 x 3000 2100 4450
1300 1150 1800 6900 14800
F1500 2U

           3U
1500 2200 x 2400 2200 3100 3000 3150 300 3900 8000 20600
3100 3350
F2000 2U

           3U
2000 2200 x 3000 2500 3600 3750 3000 x 3500 4850
400 4800 9000 25400
3700 3950
F2500 2U

           3U
2500 2500 x 3000 2500 3400 3600 3750 400 5400 9700 28800
3700 3950
F3000 2U

           3U
3000 2700 x 3300 2700 3600 3900 4050 3200 x 4600 700 5900 16400 31500
4000 4250
F5000 2U
           3U
5000 3200 x 4800 3200 4350 5400 5700 5000 1400 6400 18500 32400
Minimum Story Height according to STORY DOOR type (§®)   2U : H x 1.5 +600    3U : H x (4/3) +600
H=Height of Entrance  YT=Penetration Type
1. Please consider construction error since dimension of elevator path is the minimum value.
2. Please construct the wall of elevator path over 150§® thick.