Speed
(m/min) |
Overhead
(OH) |
Pit
(P) |
Height of
Machine Room
(MH) |
30 |
4350 |
1250 |
2000 |
60 |
4550 |
1550 |
2000 |
90 |
4750 |
1850 |
2200 |
105 |
4950 |
2150 |
2200 |
120 |
5150 |
2450 |
2200 |
|
|
|
|
Rated
Capacity
|
Speed
(m/min) |
Entrance
Specification
(OP) |
Car
(A x B) |
Elevator
Path
|
Machine
Room |
Reaction
Force
(kg) |
Passe-
ngers |
kg |
X |
Y |
S |
T |
R1 |
R2 |
6 |
450 |
60 |
800 x
2100 |
1400
x 850 |
1800 |
1500 |
2400 |
3200 |
3600 |
2000 |
8 |
550 |
60 |
800
x 2100 |
1400
x 1030 |
1800 |
1650 |
3400 |
3800 |
2400 |
90 |
1850 |
1700 |
105 |
9 |
600 |
60 |
800
x 2100 |
1400
x 1100 |
1800 |
1750 |
4000 |
2600 |
90 |
1850 |
1800 |
105 |
10 |
680 |
60 |
800
x 2100 |
1400
x 1250 |
1800 |
1900 |
3600 |
4400 |
3000 |
90 |
1850 |
1950 |
105 |
11 |
750 |
60 |
800
x 2100 |
1400
x 1350 |
1800 |
2000 |
3800 |
4900 |
3400 |
90 |
1850 |
2050 |
105 |
13 |
900 |
60 |
900
x 2100 |
1600
x 1350 |
2150 |
2050 |
2800 |
4000 |
5500 |
4100 |
90 |
2200 |
2100 |
105 |
15 |
1000 |
60 |
900
x 2100
1000 x 2100 |
1600
x 1500 |
2150 |
2250 |
6100 |
4600 |
90, 105 |
2200 |
2300 |
60 |
1800
x 1300 |
2450 |
2100 |
90, 105 |
2500 |
2150 |
17 |
1150 |
60 |
1000
x 2100
1100 x 2100 |
1800
x 1500 |
2450 |
2300 |
3000 |
6600 |
5100 |
90, 105 |
2500 |
2350 |
60 |
2000
x 1350 |
2650 |
2150 |
90, 105 |
2700 |
2200 |
20 |
1350 |
60 |
1000
x 2100
1100 x 2100 |
1800
x 1700 |
2450 |
2550 |
3200 |
4300 |
7800 |
6000 |
90, 105 |
2500 |
2600 |
60 |
2000
x 1500 |
2650 |
2400 |
90, 105 |
2700 |
2450 |
24 |
1600 |
60 |
1000
x 2100
1100 x 2100 |
2000
x 1750 |
2650 |
2650 |
4500 |
8500 |
6800 |
90, 105 |
2700 |
2700 |
60 |
2150
x 1600 |
2800 |
2550 |
90, 105 |
2850 |
2600 |
|
|
ÁÖ) |
1. Please consider construction error since
dimension of elevator path is the minimum value.
2. Please construct the wall of elevator path over 150§®
thick. |
|
|
|
 |
 |
|
 |
 |
 |
 |
|
 |
 |
 |
|
Speed
(m/min) |
Passe-
ngers |
Top Part
(OH) |
Pit
(P) |
Height of
Machine Room
(MH) |
30, 45 |
6-15 |
3900 |
1400 |
2000 |
17-24 |
4500 |
|
|
|
|
Rated
Capacity |
Speed
(m/min) |
Entrance
Specification
(OP) |
Car |
Elevator
Path
|
Machine
Room |
Reaction
Force
(kg) |
³»ºÎ |
¿ÜºÎ |
Passe-
ngers |
kg |
CA
x CB |
A
x B |
X
x Y |
MX
x MY |
R1 |
R2 |
6 |
450 |
30
45 |
800 |
1400
x 850 |
1460
x 1005 |
1850
x 1550 |
2500
x 2500 |
3600 |
N/A |
8 |
550 |
1400
x 1030 |
1460
x 1185 |
1850
x 1730 |
4050 |
9 |
600 |
1400
x 1100 |
1460
x 1255 |
1850
x 1930 |
4100 |
10 |
680 |
1400
x 1250 |
1460
x 1405 |
1850
x 2080 |
4200 |
11 |
750 |
1400
x 1350 |
1460
x 1505 |
1850
x 2180 |
4550 |
13 |
900 |
900 |
1600
x 1350 |
1660
x 1505 |
2050
x 2180 |
2800
x 2500 |
5100 |
15 |
1000 |
1600
x 1500 |
1660
x 1655 |
2050
x 2330 |
5450 |
17 |
1150 |
1000 |
1600
x 1700 |
1660
x 1870 |
2550
x 2400 |
3700 |
7500 |
20 |
1350 |
1800
x 1700 |
1900
x 1870 |
2750
x 2400 |
3950 |
8000 |
24 |
1600 |
1100 |
2000
x 1750 |
2100
x 1920 |
2950
x 2400 |
4200 |
8500 |
|
|
ÁÖ) |
1. Please consider construction error since
dimension of elevator path is the minimum value.
2. Please construct the wall of elevator path over 150§®
thick. |
|
|
 |